Setpoints

55

Mode C

Setpoint with dribble control
Dribble control provides two-speed cutoff (fast or slow feed) to enhance accuracy. Cutoff occurs
when WT≥ SP – dr – Pr.
Use the following steps to set Mode C setpoint values.

1.

Press

SETPOINT 1

or

SETPOINT 2

on front panel.

2.

Enter desired setpoint value, (display times out if no number is entered for several
seconds).

3.

Press

ENT

. Display flashes number value alternated with dr.

4.

Enter desired dribble value, then press

ENT

key. Display returns to normal operation.

5.

The setpoint value can be recalled any time by pressing the appropriate setpoint twice.

SP1

SP1-Dr

SP2

SP2-dr

Mode D

Setpoint with preact and dribble control
Slow feed cutoff occurs when WT ≥ SP – Pr. Fast feed cutoff occurs when WT ≥ SP – Pr – dr.
Use the following steps to set Mode D setpoint values.

1.

Press

SETPOINT 1

or

SETPOINT 2

on front panel.

2.

Enter desired setpoint value, (display times out if no number is entered for several
seconds).

3.

Press

ENT

. Display flashes number value alternated with Pr.

4.

Enter the desired preact value; then press

ENT

key.

5.

Enter the desired dribble value; then press

ENT

key.

6.

The setpoint value can be recalled any time by pressing the appropriate setpoint twice for
preact and a third time for dribble value.

SP1-Pr

SP1-Pr-dr

SP2-Pr

SP2-Pr-dr

Mode

Description

Setpoint

100

90

80

70

60

50

40

30

20

10

0

SP1-dr

SP2

WEIGHT

MODE C

WIRE

PLACEMENT

TB3 - 5

TB3 - 4

TB3 - 3

TB3 - 2

SP1

SP2-dr

SP1-Pr

-dr

SP2-Pr

MODE D

WIRE

PLACEMENT

TB3 - 5

TB3 - 4

TB3 - 3

TB3 - 2

SP1-Pr

SP2-Pr

-dr

100

90

80

70

60

50

40

30

20

10

0

WEIGHT

Advertising