Rice Lake IQ 700 Configurable Weight Indicator User Manual
Page 60
56
IQ 700 Installation Manual
Mode E
One setpoint with preact, dribble control, and tolerance band output
Converts setpoint two (SP2) to be a tolerance output when WT > SP1 – Lo, but < SP1 + HI.
Use the following steps to set Mode E setpoint values
1.
Enter value for
SETPOINT 1
.
2.
Press
SETPOINT 2
3.
Enter desired setpoint value, (display times out if no number is entered for several
seconds).
4.
Press
ENT
key. Display flashes number value alternated with
HI
.
5.
Enter the desired high tolerance value; then press
ENT
key.
6.
Repeat steps for the low tolerance value (Lo) (Low tolerance = SP1 – Lo).
SP1-Pr
SP1-Pr-dr
TOL
ZBD
Mode F
High-Low alarm control
Outputs with low level on when WT < SP1. High level on when WT > SP2.
Use the following steps to set Mode F setpoint values.
1.
Press
SETPOINT 1
.
2.
Enter the desired low level value, (display times out if no number is entered for several
seconds).
3.
Press
ENT
key
4.
Press
SETPOINT 2
.
5.
Enter the desired high level value, (display times out if no number is entered for several
seconds).
6.
Press
ENT
key, display returns to normal operation.
7.
The setpoint value can be recalled any time by pressing the appropriate setpoint key.
LOW
ACCEPT
HIGH
ZBD
Mode
Description
Setpoint
SP1-Pr
-dr
SP1-HI
MODE E
WIRE
PLACEMENT
TB3 - 5
TB3 - 4
TB3 - 3
TB3 - 2
SP1-Lo
SP1-Pr
100
90
80
70
60
50
40
30
20
10
0
WEIGHT
ZBD
MODE F
WIRE
PLACEMENT
TB3 - 5
TB3 - 4
TB3 - 3
TB3 - 2
100
90
80
70
60
50
40
30
20
10
0
WEIGHT
ZBD
LOW
ACCEPT
HIGH