4 normal configuration setup parameters, Jxxyyzz<cr, Table 3-7. configuration setup parameters – Rice Lake IQ 700 Configurable Weight Indicator User Manual
Page 22
18
IQ 700 Installation Manual
3.1.4
Normal Configuration Setup Parameters
You must be in the configuration mode (SW 2 closed to set the indicator from the PC) to be able to write
configuration parameters. To write commands the following
Jxxyyzz<CR>
sequence must be used. The following
parameters and their setup numbers are as follows:
Parameter 1 = Grads
J0600 03 = Both
J1100 02 = Ov.Un
J1103 06 = 6
J1200 14 = 50
J0100 00 = 500
J1101 00 = HL
J1103 07 = 7
J0100 01 = 1000
Parameter 7 = AZM Capture
J1101 01 = TGT
J1103 08 = 8
Parameter 13 = Truck in/out
J0100 02 = 1500
J0700 00 = Off
J1103 09 = 9
J1300 00 = Nor
J0100 03 = 2000
J0700 01 = .5
J1102 00 = Pos
J1103 10 = 10
J1300 01 = Tru
J0100 04 = 2500
J0700 02 = 1
J1102 01 = Zer
J1301 00 = Can
J0100 05 = 3000
J0700 03 = 3
J1103 00 = Off
J1301 01 = Str
J0100 06 = 4000
J1103 00 = Pos
J1103 01 = 1
J0100 07 = 5000
Parameter 8 = Zero Range
J1103 01 = Zer
J1103 02 = 2
J1302 00 = Off
J0100 08 = 6000
J0800 00 = 1.9
J1103 03 = 3
J1302 01 = On
J0100 09 = 8000
J0800 01 = FS
J1104 00 = Pos
J1103 04 = 4.
J0100 10 = 10000
J1104 01 = Zer
Parameter 14 = Serial
J0100 11 = 12000
Parameter 9 = Motion Band
J1104 00 = Off
J1400 00 = Off
J0100 12 = 14000
J0900 00 = Off
J1100 03 = Bat 1
J1104 01 = S1
J1400 01 = SI
J0100 13 = 16000
J0900 01 = 1
J1101 00 = Off
J1104 02 = S1.P
J1400 02 = DU
J0100 14 = 18000
J0900 02 = 3
J1101 01 = S1
J1104 03 = S1.D
(J1401 – 1405 for SI and DU)
J0100 15 = 20000
J0900 03 = 5
J1101 02 = S1.P
J1104 04 = S.P.D.
J1401 00 = Net
J0900 04 = 10
J1101 03 = S1.D
J1401 01 = GTN
Parameter 2 = Resolution
J1101 04 = S.P.D.
J1105 00 = Pos
J0200 00 = 1
Parameter 10 = Units
J1105 01 = Zer
J1402 00 = Off
J0200 01 = 2
J1000 00 = Lb only
J1102 00 = Pos
J1402 01 = 1
J0200 02 = 5
J1000 01 = Kg only
J1102 01 = Zer
J1106 00 = Off
J1402 02 = 2
J0200 03 = 10
J1000 02 = Lb/Kg Conversion
J1106 01 = 1
J1402 03 = 3
J0200 04 = 20
J1103 00 = Off
J1106 02 = 2
J1402 04 = 4
J0200 05 = 50
Parameter 11 - Setpoints
J1103 01 = S2
J1106 03 = 3
J0200 06 = 100
J1100 00 = Off
J1103 02 = S2.P
J1106 04 = 4.
J1403 00 = Off
J1100 01 = SP
J1103 03 = S2.D
J1106 05 = 5
J1403 01 = Co
Parameter 3 = Decimal Point
J1101 00 = Off
J1103 04 = S.P.D.
J1106 06 = 6
J1403 02 = De
J0300 00 = 0
J1101 01 = S1
J1106 07 = 7
J0300 01 = 0.0
J1101 02 = S1.P
J1104 00 = Pos
J1106 08 = 8
J1404 00 = 3
J0300 02 = 0.00
J1101 03 = S1.D
J1104 01 = Zer
J1106 09 = 9
J1404 01 = 6
J0300 03 = 0.000
J1101 04 = S.P.D.
J1106 10 = 10
J1404 02 = 12
J0300 04 = 0.0000
J1100 04 = Bat2
J1404 03 = 24
J1102 00 = Pos
J1101 00 = Off
Parameter 12 = Zero Band
J1404 04 = 48
Parameter 5 = Digital Averaging
J1102 01 = Zer
J1101 01 = S1
J1200 00 = Off
J1404 05 = 96
J0500 00 = 1
J1101 02 = S1.P
J1200 01 = 1
J0500 01 = 2
J1103 00 = Off
J1101 03 = S1.D
J1200 02 = 2
J1405 00 = Off
J0500 02 = 4
J1103 01 = S2
J1101 04 = S.P.D.
J1200 03 = 3
J1405 01 = Co
J0500 03 = 8
J1103 02 = S2.P
J1200 04 = 4
J1405 02 = De
J0500 04 = 16
J1103 03 = S2.D
J1102 00 = Pos
J1200 05 = 5
J0500 05 = 32
J1103 04 = S.P.D.
J1102 01 = Zer
J1200 06 = 6
(J1406 for SI only)
J0500 06 = A1
J1103 05 = tol.
J1200 07 = 7
J1406 00 = 3
J0500 07 = A2
J1103 00 = Off
J1200 08 = 8
J1406 01 = 6
J1104 00 = Pos
J1103 01 = 1
J1200 09 = 9
J1406 02 = 12
Parameter 6 = Tare
J1104 01 = Zer
J1103 02 = 2
J1200 10 = 10
J1406 03 = 24
J0600 00 = ATNR
J1103 03 = 3
J1200 11 = 20
J1406 04 = 48
J0600 01 = Auto
J1103 04 = 4.
J1200 12 = 30
J1406 05 = 96
J0600 02 = FT
J1103 05 = 5
J1200 13 = 40
Table 3-7. Configuration Setup Parameters