Options Configuration

39

4.10 Option 10 – Setpoints

This option allows an active setpoint to be operated using the display, gross, or net data. When option 10 is turned
on the selection of data that setpoint 1 operates off of is configured in 10.1 and 10.2 for setpoint 2.

Table 4-19 shows the option 10 parameters.

Table 4-19. Option 10 Parameters

For additional information on setpoints refer to Section 7 on page 52.

Refer to Section 4.12.3 on page 45 for individual serial command option parameters for Option 10.

4.11 Option 11 – Remote Input Option

The remote input option provides a means of connecting remote inputs to the indicator and option 11 is used to
configure those digital inputs to something other than to the defaults.

Table 4-20 shows the option 11 parameters.

Selecting any of these options, 11.1 - 11.5 enables the user to access the data selection for each of the inputs 1-5.

Refer to Section 4.12.3 on page 45 for individual serial command option parameters for Option 11.

Option

Prompt Display

Interpretation

Interpretation

All Off

--------

Mode not enabled (options one through ten turned off)

OP.10

OP.10 oFF
OP.10 on

Off
On – setpoint option enabled

10.1 dSP

Gr

net

Setpoint 1 uses display data
Setpoint 1 uses gross weight data
Setpoint 1 uses net weight data

10.2 dSP

Gr

net

Setpoint 2 uses display data
Setpoint 2 uses gross weight data
Setpoint 2 uses net weight data

10.3 oFF

Gr

net

Either mode
Batching while in gross display mode
Batching while in net display mode

Control the Batch 1 start
mode

10.4 oFF

(0 - 50)

No zero restriction to start the batch.
+/- 1 display grad band

Control the Batch 1 start
zero band

Option

Prompt Display

Interpretation

Off

------- Mode not enabled

OP.11

OP.11 oFF

OP.11 On

Off - remote input option disabled
On - remote input option enabled

Default Settings

Normal Batch

11.1 Input 1 (TB3-10)

Data Selection for all:
Zer Zero Scale
n-G Net/Gross toggle
tar Auto Tare
Prt Print
Sta Batch Start
Pau Batch Pause
Abo Batch Abort

Print

Print

11.2 Input 2 (TB3-9)

Tare

Start Batch

11.3 Input 3 (TB3-8)

Abort

Zero

11.4 Input 4 (TB3-7)

Net/Gr

Abort

11.5 Input 5 (TB4-5)

Print

Print

Table 4-20. Option 11 Parameters