IQ 700 Installation Manual

Table 4-15. Option 7 Configuration Parameters (continued)

NOTE: Selections 7.19 and 7.20 are available in EPROM (KDA1921-3).

To Create a File

To create a new file use the following steps:

1. Go to the desired file (7.1–7.16) using the

TARE

key.

2. Set file to on using the

lb/kg CONV

key.

3. Step to the first file line (01) using

1 SETPOINT

key.

4. Using the numeric keyboard, enter the ASCII

character or parameter code using the tables in
Section 9.0 on page 63. NOTE: all codes are
three digit decimal numbers and leading zeros
need not be entered.

5. Go to the next line using the

1 SETPOINT

key.

6. Repeat steps 4 and 5 until the file is complete.

End file with the code 999.

To Edit a File

Files may be edited in one of three ways:

A new code can be added/modified

Codes can be deleted from a file

Codes can be inserted into a file

Add/Modify a Code

To add or modify an existing code:

1. Select the file position to be added or modified

using the

1 SETPOINT

key to increase or the

2

SETPOINT

key to decrease to the desired file

number.

2. Enter a new code using the numeric keys.

Delete a Code

To delete a code:

1. Select the file position to be deleted using the

1

SETPOINT

key to increase or the

2 SETPOINT

key to decrease to the desired file number.

2. Press

CE

key.

Insert a Code

To insert a code:

1. Select the file position where the new code is to

be inserted using Setpoint keys as described
above.

2. Press

ENT

key (observe 000 code).

3. Enter the new code using numeric keys.

NOTE: Refer to the Parameter Control Chart in Section
9.0 , Table 9-2 for commands.

7.19

one

odd

evn

SPC

Transmit parity selection
Mark parity
Odd parity
Even parity
Space

7.20

oFF

on

Receive data parity
Disabled – parity observed when receiving data.
Enabled – parity is ignored when receiving data.

Option

Prompt Display

Interpretation

Advertising