2 macro file setup – Rice Lake IQ 700 Configurable Weight Indicator User Manual

Page 38

Advertising
background image

34

IQ 700 Installation Manual

4.7.2

Macro File Setup

There are eight macro files that can be accessed in any of the prime print files 1–8 (7.1 to 7.8), using the 600 series
codes listed in Table 4-10 on page 31 and Table 9-2 on page 64. Each macro file holds up to 30 ASCII characters
and parameter codes. Refer to the ASCII characters and Table 9-2 for parameter codes.

Table 4-11. Print File Definition Codes

Table 4-12. Code 600 Definitions

Table 4-13. Code 601 Definitions

Print File 7.1 – Port 1 gross mode data

Line #

Code

Code definition

01

002

STX start of text

02

600

* macro file #1 (7.9)

03

200

gross weight with lb/kg gr

04

032

SP (space)

05

601

* macro file #2 (7.10)

06

013

CR (carriage return)

07

010

LF (line feed)

08

999

end of file

Code 600 – macro file 7.9

Line #

Code

Code definition

01

065

A character

02

067

C character

03

032

SP (space)

04

105

i character

05

110

n character

06

099

c character

07

046

. (period)

08

013

CR (carriage return)

09

010

LF (line feed)

10

999

end of file

Code 601 – macro file 7.10

Line #

Code

Code definition

01

402

date per setup

02

032

SP (space)

03

401

time per setup

04

999

end of file

Advertising