Setpoints

57

Table 7-1. Setpoint Configuration Modes

Mode G

Over/Under checkweigh control
Provides High, Low, and Accept outputs except a direct entry is made for a target weight and high/
low settings become dependent.
Use the following steps to set Mode G setpoint values.

1.

Press

SETPOINT 1

2.

Enter the desired target value; then press

ENT

.

3.

Press

SETPOINT 2

4.

Enter the desired high tolerance (HI) value and press

ENT

.

5.

Enter the desired low tolerance (L0) value and press

ENT

.

LOW

ACCEPT

HIGH

ZBD

Manual

Batching

Mode

The manual batching mode operates as follows:

1.

Press the

START

key located in the lower left corner of the front panel. The setpoint LED is on.

2.

Setpoint 1 is activated if enabled. If enabled, skip step D.

3.

When the displayed weight reaches or exceeds the setpoint value, the setpoint is deactivated.

4.

The unit enters a pause mode locking out zero, net/gross, and tare keys during run. During Pause, the
tare key is still functional.

5.

Press the

START

key again and setpoint 2 is activated.

6.

When the display weight reaches or exceeds the setpoint 2 value, the setpoint is deactivated.

7.

Press

START

and the unit returns to normal operation with all keys active.

If the

CE

key is pressed at any time during the batching process, the setpoints are deactivated and the unit

returns to the normal operating mode.

Automatic

Batching

Mode

The automatic batching mode operates as follows:

1.

Press the

START

key, and the setpoint LED light turns on.

2.

The unit is switched to the net weighing mode.

3.

An automatic auto tare operation takes place.

4.

Setpoint 1 is activated.

5.

When the displayed weight reaches or exceeds the setpoint value, the setpoint value is
deactivated.

6.

The setpoint indicator LED turns off

7.

Timer 1 phase begins. If timer 1 is turned off, the unit enters an indefinite pause mode and
the start key must be pressed to continue to setpoint 2. Otherwise the unit pauses for 1 to
10 seconds, depending on the timer 1 value.

8.

Upon timeout (or pressing the

START

key), the unit will do a demand printout (1 or 3 lines

depending upon configuration).

9.

An auto-tare operation takes place.

10. Setpoint 2 is activated until the displayed weight reaches or exceeds the setpoint value.
11. Timer 2 phase begins and the same conditions apply as in number 7.
12. Upon timeout, the unit does a demand printout.
13. The unit returns to normal operation in the gross mode.

If the

CE

key is pushed at any time during the batching process, the batch process is aborted, the

setpoints deactivated, and the unit returning to normal operating mode. During batch run mode,
front panel functions are disabled.

Mode

Description

Setpoint

MODE G

WIRE

PLACEMENT

TB3 - 5

TB3 - 4

TB3 - 3

TB3 - 2

100

90

80

70

60

50

40

30

20

10

0