2 parameter control code chart, 3 display and error messages – Rice Lake IQ 700 Configurable Weight Indicator User Manual

Page 70

Advertising
background image

66

IQ 700 Installation Manual

9.2

Parameter Control Code Chart

Use the following code values for parameter descriptions listed in Table 9.2 when specifying the format string. The
actual character depends on the character mapping used by the output device.

Table 9-2. Parameter Control Code Chart

9.3

Display and Error Messages

Code

Description

Code

Description

Code

Description

200

Gross weight & LB/KG GR

240

Truck gross lb/kg GR

600

Macro file 1 (7.9)

201

Gross weight & LG/KG

241

Truck gross only

601

Macro file 2 (7.10)

202

Gross weight

242

Truck tare lb/kg TR

↕ (7.11 – 7.15)

203

Gross weight (no 0 blanking)

243

Truck tare only

607

Macro file 8 (7.16)

244

Truck net lb/kg NT

210

Net weight & LB/KG NT

245

Truck net only

700

Delay per setup

211

Net weight & LN/KN

800

Setpoint 1 & SP1 data

212

Net weight

300

Status character

801

SP1 data only

213

Net weight (no 0 blanking)

400

Time & date per setup

802

Setpoint 2 & SP2 data

401

Time per setup

803

SP2 data only

220

Tare weight & LB/KG TR

402

Date per setup

221

Tare weight & LT/KT

500

Ident no. & ID. NO.

999

End of file

222

Tare weight

501

Ident no. only

223

Tare weight (no 0 blanking)

502

Tag

503

held ID NO. & ID. NO.

230

Total WEIGHT & lb/kg TOTAL

504

Held ID NO. (no label)

231

Total weight & LA/KA

510

TICKET NO. & counter data

232

Total weight only

511

Counter data only

233

Total weight (no 0 blanking)

Display Messages

Display

Explanation

Corrective Action

Err 1
Err 1a, 1b, 1c

Loss of configuration
Loss of option configuration

Enter configuration
Enter option mode reconfigure

Err 2

Loss of zero calibration

Enter digital calibration mode and recalibrate unit

Err 3

Loss of span calibration

Err 5

Loss of auto tare

Acquire tare

Err 6

Loss of auto zero

Acquire zero

Err 9

Not in span calibration

Program in desired value before entering

Err 10H
Err 10L

Input > 3.3mV/V @ full scale
Input < 0.4mV/V @ full scale

Recalibrate span so FS ≤ 3.3mV/V
Recalibrate span so FS ≥ 0.4mV/V

Err 10P
Err 10-

PTZ (push to zero) > 2.0%
PTZ > weight used for span calibration

Perform zero calibration

CAL

Indicates successful calibration

OL

Gross overload

Check load cell wiring

UL

Gross underrange

Table 9-3. Display and Error Messages