IQ 700 Installation Manual

Table 4-2 shows the option 2 configuration parameters

.

Table 4-2. Option 2 Configuration

Option

Prompt

Display

Interpretation

Notes

All off

--------

Mode not enabled (options 1 through 10
turned off)

OP.2

OP.2 o F
OP.2 o n

Off Analog option disabled
On Analog option enabled

2.1 dSP

Gr

net

Analog tracks display
Analog tracks gross weight
Analog tracks net weight

2.2 P.1

P.2

Indicator data out on port 1 (to analog)
This port is not used

Use standard indicator setup for serial configuration
under menu 14 (configuration Switch S-2 closed) to
establish communications before using the option 2
menu. Port 1 from the indicator to the analog module
must be set for the desired baud rate and be in
continuous output mode. In the option 2 menu, set the
indicator port to 1. On analog board S1, set baud rate
switches (1 and 2) to match menu 14.

2.3 OFF

dE

Co

Analog module does not pass serial data
Analog module outputs serial on demand
Analog module outputs serial continuously

2.4

12
24
48
96

Pass-through serial output baud rate
1200 baud
2400 baud
4800 baud
9600 baud

2.5 Zr

Enter weight value for analog zero using
the numeric keys. The TARE key stores
new value; the display responds with
ENTER.

The display for parameters 2.5 through 2.8 alternate
between the parameter selection and the actual data
value currently entered. This alternation will continue
until the data for the parameter has been increased or
decreased.

NOTE:

After entering new data, use

TARE key to store. The display will again resume
switching between parameter and data.

2.6 FS

Use the same procedure as 2.5 to enter
analog full scale value.

2.7 Zr.A

ZERO TRIM: While measuring analog
output, use lb/kg CONV and PRINT keys
to increment/decrement the zero value.
Increment/decrement function forces a
test mode zero output. The TARE key
stores the new value.

2.8 SP.A

SPAN TRIM: Same as 2.7 except a span
test mode output is provided.

Advertising