Example:
Weighing in 100% of a sample material.
Settings (changes in the factory settings required for this example):
Setup: Application: Weighing in percent
Setup: PRTPROT (printout): 7.7.x (COM1) (see “Configuration” for options)

If the weight is too light,
the error code

Inf 29

is shown

on the main display.

Reduce the minimum load
setting.

5. Continuing filling the

container until the target
amount is reached
(in this example, 100%)

p

6. Print the result

pRef

+

20 %

Configured printout:

wRef

+

0.085 kg

see page 82

G#

+

1.080 kg

T

+

0.675 kg

N

+

0.423 kg

Prc

+

100 %

-------------------

69

69

1. Place empty container on

the platform

)

2. Tare the scale

Note: If the automatic tare
function is enabled, you do
not need to press the ) key
to tare the scale; the tare
weight is saved automatically
when you place the container
on the platform

3. Add reference material in

accordance with reference
percentage
(in this example, 85 g, = 10%)

O

4. Activate calculation of

the reference weight.
The calculation is based on
the active net weight value
and the reference percentage
entered.