CANOGA PERKINS 9145E NID Software Version 4.10 User Manual

Page 124

Advertising
background image

9145E NID Software User’s Manual

Diagnostics

Service Activation Testing

112

Figure 4-64 Modify SA Profile screen

3. Type the number of the field you wish to change and press Enter.

4. Change the value and press Enter.

NOTE: Option 26, PCP Equivalency, is necessary only if the CoS/PCP attribute is set to “no”.
This indicates sets of PCPs belonging to the same CoS. It is used for CoS Preservation with vari-
able PCP test.

5. To view or edit Frame format, type 18 and press Enter. The L2 Frame Format screen

opens (Figure 4-65).

6. To view or edit L3 Frame Formats, on the L2 Frame Format screen, type 1 and press

Enter. Press the space bar to select L3 (Figure 4-66).

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-761-0-0 V41.66 23:47:13
------------------------------MODIFY SA PROFILE--------------------------------
ID: 1 Name: test Ref. Counter: 0

1) UNI MTU (bytes) : 64 15) On step failure : exit
2) EVC MTU (bytes) : 64 16) Coloring Method : DEI
3) CE-VLAN ID pres. : yes 17) Frame Size mix : a
4) CoS/PCP preserv. : yes 18) Frame Format
5) Ucast Delivery : Deliver 19) Delay acceptance criteria
6) Mcast Delivery : Deliver 20) Delay Variation acceptance criteria
7) Bcast Delivery : Deliver 21) Loss Ratio acceptance criteria (%) : 0.00
8) L2CP Profile : default
9) Yellow PCP List : 22) DM/SLM Frame Rate (pps) : 14
10) Rate step decrease (%) : 10 23) DM/SLM Frame Size (bytes) : 64
11) Rate step length (s) : 10 24) DM Tool : dm
12) CBS test Line Rate (Mbps) : 10 25) Directionality : single
13) CBS test traffic priority : Test 26) PCP equivalency
14) CBS test cycles : 1 27) Steps to execute

Select [1-27]: