CANOGA PERKINS 9145E NID Software Version 4.10 User Manual

Page 128

Advertising
background image

9145E NID Software User’s Manual

Diagnostics

Service Activation Testing

116

Figure 4-69 SA Class of Service to PCP equivalency map screen

12. Type the number of the class you wish to change and press Enter. Type equivalent PCPs

and press Enter. Press Esc to return to the previous screen.

13. To enable steps to execute, type 27 and press Enter. The Steps to Execute screen

(Figure 4-70) opens. By default all steps are enabled.

14. Enter the number of the step you wish to enable or disable and press Enter. Press the

Space bar to enable or disable a step.

Figure 4-70 Steps to Execute screen

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-761-0-0 V41.66 23:47:13
--------------------- SA Class of Service to PCP equivalency map ---------------

SA Profile id: 20 SA profile name: sa1

CoS ID Equivalent PCPs
------ ---
0 0,1,2,3
1 N/A
2 4
3 N/A
4 N/A
5 5,6
6 N/A
7 7

Select Class to change to change [0-7]:

------------------------------------Messages----------------------------------

Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-761-0-0 V41.66 23:47:13
-------------------------------- STEP TO EXECUTE -------------------------------

1) UNI MTU size : enable
2) EVC MTU size : enable
3) CE-VLAN ID Preservation : enable
4) CoS/PCP preservation : enable
5) CoS to PCP mapping validation : enable
6) Service frame delivery : enable
7) L2CP Control Protocol Processing : enable
8) CIR test : enable
9) Policing test : enable
10)CBS test : enable

Select [1-10]:

------------------------------------Messages----------------------------------

Advertising