Figure 11-29 – CANOGA PERKINS 9145E NID Software Version 4.10 User Manual

Page 245

Advertising
background image

Service OAM

9145E NID Software User’s Manual

Maintenance End Points

233

8. To change the Data TLV size, type 7 and press Enter. This value indicates the amount of

data in each packet. Type a value between 0 and 1491 and press Enter.

9. To change the Data TLV payload, type 8 and press Enter. Type the string that you want to

send in a loopback message and press Enter.

10. If you chose sweep mode in step 1, you can enter a start size and end size:

To enter a start size, type 5 and press Enter. Type a number from 30 to 1488 and
press Enter.

To enter an end size, type 6 and press Enter. Type a number from the range dis-
played on the screen and press Enter.

11. To send the loopback request, type S and press Enter.

12. Press Esc to return to the Maintenance End Point Attributes screen.

Figure 11-29 Unicast Loopback Monitoring screen

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V04.10 05:15:27
-------------------------------LOOPBACK MONITORING-----------------------------

MEP ID: 100
Mode: Unicast regular
Destination: MEP ID : 200
P-Bit value: 7
DE bit value: 0
Transmission rate (pps): 10
Number of packets: 30 (0 - unfinished)
Data TLV size: 0 LBM size: 64 (31)
Data TLV payload: << randomly generated >>

Loopback Status: Active

First transaction ID: 1
Transmitted LBMs: 30
Received LBRs: 30

Select (S) to stop, (R) new request, (Ctrl+R) exit without aborting:
------------------------------------Messages-----------------------------------

Advertising