CANOGA PERKINS 9145E NID Software Version 4.10 User Manual
Page 81
Diagnostics
9145E NID Software User’s Manual
Network Performance
69
8. In the Version field, type the Test Distribution protocol version (1,2, 3 or 4) used when
distributing results and press Enter. Use the version numbers in Figure 4-25 to allow the
EMS system to receive the corresponding PM, CPM or SAM test result data.
Figure 4-24 Network Performance Distribution Connection Setup screen
Figure 4-25 Distribution Connection Versions
Canoga Perkins Corp. Ethernet Network Interface Device 29-JAN-2009
9145E-101-1-0 V04.10 11:20:59
-------------NETWORK PERFORMANCE DISTRIBUTION CONNECTION SETUP-----------------
1) IP Address
2) State Disabled
3) Description
4) Retries 3
5) Timeout 5
6) Version 4
Enter a valid class A, B or C IP Address.
------------------------------------Messages-----------------------------------