Figure 11-7 – CANOGA PERKINS 9145E NID Software Version 4.10 User Manual

Page 219

Advertising
background image

Service OAM

9145E NID Software User’s Manual

SOAM Configuration

207

Figure 11-7 SOAM Configuration screen

NOTE: You can perform system-level configuration before or after you configure Maintenance
Domains or other entities.

4. On the SOAM System Level Configuration screen (Figure 11-8), type 1 and press Enter.

5. Press the Space bar to select Enabled or Disabled and press Enter. If Service OAM

procedures are disabled for the system, no Service OAM packets are captured and
processed. Instead, all Service OAM packets received by the 9145E NID are
transparently forwarded, using the same rules as for data plane traffic.

6. When you are prompted to change SOAM status, type Y and press Enter to save the

setting, or type N to return to the original setting.

7. To select a Chassis ID Format, type 2 and press Enter. Select one of the following

settings:

MAC Address, and press Enter. The Chassis ID value is read only. You cannot
change the value on this screen.

Network Address, and press Enter. The Network Address value is read only. You
cannot change the value on this screen.

Locally Assigned, and press Enter. This selection allows you to enter a custom
string.

Canoga Perkins Corp. Ethernet Network Interface Device 02-JAN-2009
9145E-101-1-0 V04.10 05:15:27
------------------------------SOAM CONFIGURATION-------------------------------

1) System level configuration

2) Maintenance Domains (MDs)
3) Maintenance Associations (MAs)
4) Maintenance Entity Groups (MEGs)
5) Maintenance End Points (MEPs)
6) Maintenance Intermediate Points (MIPs)

7) Configuration Error List

Select [1-7]:

------------------------------------Messages-----------------------------------