Terminal connections

Tape-end output connections

External timer input connections

External timer

O

oooo

.1 2. iGND

IN RESET OUT,

ALARM

O

O

EXT

TIMER

o

Q tea c::a

oo

IN OUT

WARNING
/REC OUT

L

t

APE END

out

REC IN GND ^TIME ADJ IN

When the cassette tape comes to its end during

recording, the alarm device which has been installed

externally is triggered.

Auto OFF output connections and

recording output connections

External
interface

a.

O

o

O

o

O

.1 2. |GND

IN RESETOUT

AURM

A

ooo

EXT

TIMER

¿a.

O O

Alarm lamp

IN OUT

WARNING
/REC OUT

^^TAPE END OUT

REC IN GND ^TIME ADJ IN

An external timer can be used for recording.

• Select ON for EXT TIMER IN on the menu screen

shown on P7 TERMINAL INPUT SELECT, and set
the front panel TIMER MODE button to EXT
(external timer recording).

The unit’s power is turned off, and recording is

started by the signal from the external timer.

External timer signal

Power OFF

External timer

recording

Power OFF

Recording proceeds in the recording
mode which was set by menu screen P4
RECORDING MODE.

The auto OFF output and recording output
connections are the same. Select between them

using ERROR WARN/REC OUT on the menu screen
shown on P7 TERMINAL OUTPUT SELECT.

Auto OFF output
When a problem has occurred in the unit, the alarm
device which has been installed externally is
triggered.
In this case, the error code appears on the display.

(See page 102.)

Recording output

When the unit is set to the recording mode, the alarm
device which has been installed externally is
triggered.