RS-232C

Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] QDP [ETX]

[STX] DPPmm [ETX]

Parameter

mm = C: Center

LB: Bottom left
LT: Top left
RB: Bottom right
RTiTop right

Queries the position where the characters are to be
displayed on the monitor screen.

[STX] QDS [ETX]

[STX] LDSm [ETX]

Parameter

m = i: Field playback

R: Frame playback

Queries whether field playback or frame playback is to be

initiated when still-picture playback is performed.

[STX] QDW [ETX]

[STX] LDWm [ETX]

Parameter
m= W: WARNING

The control signals continue to

be output.

R; REC

The control signals are output
only during recording.

Queries the setting for how the control signals are to be
output to the component connected to WARNING/REC
OUT on the rear panel terminal section when a problem has
occurred in the unit.

[STX] QDX [ETX]

[STX] LDXm [ETX]

Parameter

m= V: VIDEO OUT

Video signal output connector

E: EXTSWIN

External sequential switcher

signal input connector

Queries the function of the EXT SWIN/VIDEO OUT

connector on the rear panel.

[STX] QFS:nn [ETX]

Parameter
nn= 01—12: Free-set timer

number

[STX] LFSnn:mmdd:p [ETX]

Parameter

nn = 00: Free-set timer is not set.

01—12: Free-set timer number

mm - 01—12: Month
dd= 01—31: Day

p = 0: Sunday

1: Monday

2: Tuesday
3: Wednesday

4: Thursday

5: Friday
6: Saturday
F: Power OFF throughout the day

Queries the free-set timer setting.

[STX] QHI [ETX]

[STX] HTIm [ETX]

Parameter
m= A: REWIND^REC

R: REC

S: STOP

Queries the unit’s operation mode that Is to be established

when the tape is inserted.