RS-232C

Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] QiR [ETX]

[STX] LUlmdata [ETX]

Parameter
m = R: READ OK

E: READ NG

data = U7U6UsU4U7U3U2UiUo

The user ID is returned as an 8-
character ASCil code.
Binary 4BIT x8

ASCII code; 0—9, A—F

Queries the user ID recorded on the playback tape.

[STX] QIW [ETX]

[STX] LIWabcdefgh:ijklmnop [ETX]

Parameter

a—p = 1—8: Program registration

number (PGM1—PGM8)

F; Timer is not set.

Queries the weekly timer and daily timer setting.

a = Program 1 on
b = Program 1 on
c = Program 1 on
d = Program 1 on
e = Program 1 on
f = Program 1 on
g = Program 1 on
h = Daily program
i = Program 2 on

j - Program 2 on

k = Program 2 on
I = Program 2 on
m = Program 2 on
n = Program 2 on

0

= Program 2 on

p= Daily program

Sunday
Monday

Tuesday
Wednesday
Thursday

Friday

Saturday

1

Sunday

Monday

Tuesday

Wednesday

Thursday

Friday

Saturday

2

[STX] QLA:m [ETX]

Parameter

m = 1: Operation mode

D; Time setting

[STX] LAmn [ETX]

Parameter
m = I: Operation mode

Queries the operation mode that is to be established when
an alarm signal has been input at the tape-end position, and

the duration of the alarm recording and/or sensor recording.

n = S: STOP

Stop mode at tape-end
position

C: CONTINUE

Alarm signal input is
ignored.

m = D: Time setting

n = 0: 30 seconds

1: 1 minute

2: 1 minute and 30 seconds
3: 2 minutes
4: 3 minutes
5: 6 minutes
6: 10 minutes
7: CONTINUE

Recording continues until

the tape-end.

MANUAL
Recording is performed only

while an alarm signal is

input.

8

:

89