RS-232C

Search control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] SASidata [ETX]

Parameter

data = nn;d

nn - 0—9: Atarm number
d = F:

Forward direction

N:

Reverse direction

[STX] SAS [ETX]

Searches the alarm number designated by the parameter in

the direction designated by the parameter.

The unit is set to STILL mode upon completion of the
search.

If the designated position is an illegal position (that is, the

target position does not exist), error code ERT is returned
from the unit, and the STOP mode is established.
If the OSP (STOP) command or OEJ (tape EJECT)
command is assigned during operation, error code ERI is
returned from the unit.
If the unit’s operation mode has been changed by an

operation at its front panel, error code ERF is returned from

the unit.

If the tape reaches its start or end during operation, error

code ERP is returned from the unit.
When data differing from the reference data has been sent,
error code ERE is returned from the unit.

<Note>

This command is not acknowledged while a search control
command is being processed or while one of the following
modes is established.

EJECT, REC, REC PAUSE, REC CHECK, POWER OFF

[STX] SCP:data [ETX]

Parameter

data = ghmmssff

(CTL data referenced)

g = Blank : With a positive (+)

value

- sign; With a negative (-)

value

[STX] SCP [ETX]

h= 0—9;
mm = 00—59:

ss = 00—59:

Hours

Minutes
Seconds

ff =

00 (fixed): Frames

Searches the counter value designated by the parameter.
Playback is started upon completion of the search.
If the designated position is an illegal position (that is, the

target position does not exist), error code ERT is returned

from the unit, and the STOP mode is established.

If the OSP (STOP) command or OEJ (tape EJECT)

command is assigned during operation, error code ERI is

returned from the unit.

If the unit’s operation mode has been changed by an

operation at its front panel, error code ERF is returned from
the unit.

If the tape reaches its start or end during operation, error

code ERP is returned from the unit.
When data differing from the reference data has been sent,
error code ERE is returned from the unit.

<Note>

This command is not acknowledged while a search control
command is being processed or white one of the following
modes is established.

EJECT, REC, REC PAUSE, REC CHECK. POWER OFF