Rs-232c, Query control commands – Panasonic AG-DTL1P User Manual

Page 91

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

RS-232C

Query control commands

Data transmitted by PC

tSTX] QLP:n [ETX]

Parameter
n = 0—3
Up to the last 4 sets of data are

designated by this parameter with 0

serving as the latest data.

Data returned from unit in response

[STX] LPLnn:data1;data2 [ETX]

Parameter
nn = 00—99: Alarm number

datai = yyyymmdd

yyyy = 2000—2099: Gregorian

calendar

mm:

01—12: Month

dd=

01—31: Day

data2 = hhmmss

hh = 00—23: Hours (24-hour system)

mm - 00—59: Minutes

ss - 00—59: Seconds

Description of command

Queries the POWER LOSS MEMORY data.

[STX] QLT [ETX]

[STX] LTMm [ETX]

Parameter
t = 0: 3-hour recording

1: 9-hour recording

2: 12-hour recording

3: 18-hour recording
4: 24-hour recording

5: 48-hour recording

6: 72-hour recording

7: 96-hour recording
8: 120-hour recording
9: 180-hour recording
A: 240-hour recording

B: 360-hour recording

C: 480-hour recording

D: 960-hour recording

Queries the recording/playback time mode setting.

[STX] OL2 [ETX]

[STX] LBZm [ETX]

Parameter

m = N: Buzzer ON

F: Buzzer OFF

Queries the setting of the buzzer operation during alarm

recording and/or sensor recording.

[STX] QMA [ETX]

[STX] LMAm [ETX]

Parameter

m = F: Search mode OFF

M: Memory stop mode

A: Alarm search mode

Queries the search mode.

91