Rs-232c, Search control commands – Panasonic AG-DTL1P User Manual

Page 71

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

RS-232C

Search control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] SCS:data lETX]

Parameter

data - ghmmssff

(CTL data referenced)

g = Blank : With a positive (+)

value

- sign: With a negative (-)

value

[STX]

ses

[ETX]

h =

0—9

: Hours

mm = 00—59

: Minutes

ss =

00—59

: Seconds

ff =

00 (fixed): Frames

Searches the counter vaiue designated by the parameter.

The unit is set to STiLL mode upon completion of the
search.

It the designated position is an illegal position (that is, the

target position does not exist), error code ERT is returned
from the unit, and the STOP mode is established.

If the OSP (STOP) command or OEJ (tape EJECT)

command is assigned during operation, error code ERI is

returned from the unit.

If the unit's operation mode has been changed by an

operation at its front panel, error code ERF is returned from
the unit.

If the tape reaches its start or end during operation, error

code ERP is returned from the unit.
When data differing from the reference data has been sent,
error code ERE is returned from the unit.
<Note>

This command is not acknowledged while a search control

command is being processed or while one of the following
modes is established.

EJECT, REC, REC PAUSE, REC CHECK, POWER OFF

[STX] SPT;data [ETX]

Parameter

data = ghmmssff

(CTL data referenced)

g = Blank : With a positive (+)

value

- sign: With a negative (-)

value

[STX] SPT [ETX]

h=

0—9

mm = 00—59
ss =

ff =

00—59

00—29

Hours
Minutes

Seconds

Frames

Searches up to the position designated by the parameter.

The unit is placed in the STILL mode upon completion of
the playback.

If the designated position is before the current position, the
STILL mode is established without playing back the tape.
If the OSP (STOP) command or OEJ (tape EJECT)

command is assigned during operation, error code ERI is

returned from the unit.
If the unit's operation mode has been changed by an

operation at its front panel, error code ERF is returned from
the unit.

If the tape reaches its start or end during operation, error

code ERP is returned from the unit.
When data differing from the reference data has been sent,

error code ERE is returned from the unit.
<Note>

This command is not acknowledged while a search control

command is being processed or while one of the following
modes is established.

EJECT, REC, REC PAUSE, REC CHECK, POWER OFF

71