RS-232C

Query control commands

Data transmitted by PC

Data returned from unit in response

Description of command

[STX] QTR (ETX]

[STX] HTRm:b [ETX]

Parameter
m = 0: 2% oi tape remaining

1: 10% of tape remaining

2: 20% of tape remaining
3: 30% of tape remaining
F: (OFF) no warning

b = N: Warning is sounded by buzzer.

F: (OFF) warning is not sounded

by buzzer.

Queries the setting for the remaining tape amount for which

REMAiN is to fiash on the display tube as a warning

display, and the setting for the buzzer to sound when the
tape-end position is about to be reached.

(When a 120-minute tape is used)

[STX] QTY:n [ETX]

Parameter
n= 1—6: Recording type (RT1—6)

1

:

2

:

3:

4:
5:

6

:

7:
8

:

9:

A:

B:

[STX] LTYn:t:abcdefgh [ETX]

Parameter
n= 1—6: Recording type (RT1—6)

t = 0: 3-hour recording

9-hour recording

12-hour recording
18-hour recording

24-hour recording
48-hour recording

,72-hour recording

96-hour recording

120-hour recording
180-hour recording

240-hour recording

360-hour recording

C: 480-hour recording
D: 960-hour recording
F: OFF (setting of TIME MODE

button is complied with)

a = Y or N: for setting cameras No.1

and 2

b = Y or N: for setting cameras No.3

and 4

c = Y or N: for setting cameras No.5

and 6

d = Y or N: for setting cameras No.7

and 8

e = Y or N: for setting cameras No.9

and 10

f = Y or N: for setting cameras No.11

and 12

a = Y or N: for setting cameras No. 13

and 14

h = Y or N: for setting cameras No.15

and 16

Y; Used
N: Not used

Queries the setting for the combination of the recording time
mode and number of cameras.

99

Advertising