Setting menus

Menu page P4

(RECORDING MODE)

P4

FIELD/FRAME

FIELD

PICTURE QUALITY

HIGH

REC-TYPE

RT0(OFF+16)

[ALARM/SENSOR REC]

MODE

OFF

FIELD/FRAME

FIELD

PICTURE QUALITY

HIGH

DURATION

O.Smin

BUZZER

OFF

REPEAT

OFF

GROUP ALARM1

RTO(OFF+16)

GROUP ALARM2

RTO(OFF:4;16)

ALARM/SENSOR REC screen

Menu item

Description of function

MODE

For setting what recording operation is to be performed when an

alarm signal has been input.
OFF : The unit operates normally regardless of whether an

alarm signal is input.

ALARM/SENSOR:

Alarm recording or sensor recording is performed.

ALARM : Alarm recording is performed.
SENSOR; Sensor recording is performed.

FIELD/FRAME

For selecting field recording or frame recording when alarm

recording or sensor recording is to be performed.
FIELD : Field recordina is oerformed.
FRAME : Frame recording is performed.

PICTURE

For setting the picture quality when alarm recording or sensor

QUALITY

recording is to be performed.
HIGH : Recordina is performed at a hiah aualitv.
NORMAL : Recording is performed at the standard quality.

NO CHANGE : Recording is performed at the current quality setting.

DURATION

For setting t
O.Srhin

f.Omin
1.5min

2.0min

3.0min

S.Omin

fOmin

CONTINUE
MANUAL

he length of the alarm recording or sensor recording.

Recording for 30 seconds.
Recording for 1 minute.
Recording for 1 minute and 30 seconds.
Recording for 2 minutes.
Recording for 3 minutes.
Recording for 5 minutes.
Recording for 10 minutes.
Recording continues until the tape-end.
Recording is performed only while an alarm signal is

input.

BUZZER

For setting whether the buzzer is to sound during alarm recording or

sensor recording.
ON : The buzzer sounds. It stops when any one of the function

buttons is pressed.

OFF: The buzzer does not sound.

REPEAT

For setting whether alarm recording or sensor recording is to be
performed if an alarm signal has been input while repeat recording is
underway or while the tape is being rewound.
OFF: Alarm recording or sensor recording is not performed when

the tape is being rewound.

If an alarm signal has been input even when tape rewinding is

completed, alarm recording or sensor recording is perfomried.

ON : Alarm recording or sensor recording {or both) is forcibly

performed even while the tape is being rewound.

GROUP ALARM1

For selecting the recording type from what was registered on menu

page P3 when alarm recording or sensor recording is to be
performed if an alarm signal is input to ALARM IN 1.
RTO—RT7

GROUP ALARM2

For selecting the recording type from what was registered on menu
page P3 when alarm recording or sensor recording is to be
performed if an alarm signal is input to ALARM IN 2.
RTO—RT7

The underlining indicates the factory mode setting.

<Note>
When RT7 has been selected as the REC-TYPE item setting, the

FIELD/FRAME item setting is overridden and frame recording is forcibly

initiated.