A&D Weighing AD-4406 User Manual

Page 25

Advertising
background image

AD-4406 Weighing Indicator

Page 23

Display and Other General Settings

Item

Parameter

Description

* 0

5 times/s

F04
Display update rate

1

10 times/s

The selection for the unstable
condition.

1 x

Key click (

ON/OFF

)

2 x

LoLo /Zero band

3 x

LO

4 x

OK

5 x

HI

F05 [Type2]
Buzzer

6 x

HiHi/Batch finish/Full

Left: Item, select using the

key

Right: parameter, select using the

1

key

0: no sound, 1: continuous
2: 4 times/s, 3: 2 times/s
4: 1 time/s,

5: 1 time/2s

Initial value is 11, others x0

F06
Device ID (Address)

00 to

99

Command address
or Device ID

Initial setting is 00.

* 0

Not automatically off

F07
Auto power off

1

5 minutes

Stable and not using for 5 min.,
automatically power off.

s:

second.

*: Initial settings.

Key Switch

Item

Parameter

Description

x 0

No function

x 1

Serial data output 1

x 2

Serial data output 2

x 3

Accumulation (M+)

x 4

"totAL" display

x 5

Setting setpoint

x 6

Start comparator,
batch

x 7

Stop comparator,
batch

x 8

Stop buzzer sound

x 9

Unit change

F10 [Type2]
F1 key function

x A

Hold start / release

Left: Priority, select using the

1

key

Right: Function (listed), select

using the

key

The first priority is operated by
pressing and releasing the key
quickly, pressing the key for
more than two seconds, lower
priority functions are displayed
sequentially.

Initial value is 13, others x0

F11 [Type2]
F2 key function

same as F10

Initial value is 11, others x0

2 0

F12 [Type2]
Disabling keys

A key is selected by the left
parameter

A key condition is selected by
the right parameter:
When specifying 1 at the right
parameter, this key does not
work.
Use the function to avoid
unintentional operation of 6
keys in the table at the left.

*:

Initial settings

*

0 enable

1 disable

key

1 ZERO key

2 TARE key

3

NET/GROSS

key

4 F1 key

5 F2 key

6 ON/OFF key

key

6.2. F-Functions

Advertising