A&D Weighing AD-4406 User Manual

Page 27

Advertising
background image

AD-4406 Weighing Indicator

Page 25

Comparator

Item

Parameter

Description

* 0

Not used

1

Upper/lower limit comparison (2 Limits setting)

2

Upper/lower limit comparison (Target and allowance)

3

Upper/lower limit comparison (Target and % allowance)

4

HH/Hi/OK/Lo/LL comparison (4 Limits setting)

5

HH/Hi/OK/Lo/LL comparison (Target and allowance)

6

HH/Hi/OK/Lo/LL comparison (Target and % allowance)

7

Check weighing 1

8

Check weighing 2

9

Check weighing 3

10

Simple batch 1

11

Simple batch 2

F22
Comparator function

12

Simple batch 3 (Loss in weight)

10/11

Includes zero band (1)

20/21

Includes minus (1)

30/31

Stable (0) /All time (1)

F23 (F22=1-6)
[Type2]
Validation of
comparison

40/41

All time (0) /Start, stop (1)

Initial settings are
11,21,31,40

10/11

Tare when start (1)

20/21

Stop after Full by key (0) /Auto (1)

30/31

Over/Under judgment:
after dribble flow (0) / Batch finish (1)

F23 (F22=10-12)
[Type2]
Sub function for
batch weighing

40/41

Start with press and hold TARE (1)

Initial settings are
11,21,31,40

* 0

Over

1

Under

F24
Relay output
selection

2

Finish/Full (F22=9,10,12)

Effective when
F22=7,9,10,12

F25
Batch finish output time

0.0 to

9.9

Relay on time by 0.1second step
(0.0:continuous to zero band)

Initial setting is 0.0

F26
Zero band

-999999 to 999999

Initial setting is 0

*:

Initial settings

Hold Function

Item

Parameter

Description

* 0

No hold

1

Manual hold

2

Auto hold

F27
Hold mode

3

Manual/auto hold

F28
Averaging time

0.0 to

9.9

Averaging time by 0.1second step
(0.0:hold at averaging start)

Initial setting is 0.0

*:

Initial settings