Action of Accumulating Data

When accumulating data, the display blinks once.

If the accumulated data is stored, the M+ mark is displayed.

Caution

This function can not accumulate data with a different unit. Specify a

unit before use.

Display of Accumulated Data

When setting to CF08 1 (Effective accumulation function) and pressing the key that

allows accumulation display, totAL is displayed and the total data is displayed

with the M+ mark blinking. Pressing the TARE key alternatively displays the

accumulated data and the accumulation count.

Pressing the ESC key, the weight data is displayed.

The total data can be output. Refer to "Output of Accumulated Data".

Undoing the Accumulated Data

The last weight data can be deduced from the accumulated data unless new data

has been accumulated.

Step 1

Press the key assigned to operate the function to display totAL and the

accumulated data.

Step 2

Press and hold the +/- key for more than 3 seconds. The display blinks once and

the data accumulated before accumulating the last weight data is displayed.

Caution

External input can not be used.

Clearing the Accumulated Data

Step 1

Press the key assigned to operate the function to display totAL and the

accumulated data.

Step 2

Press and hold the ZERO key for more than 3 seconds. The display blinks once

and the accumulated data is cleared.

Caution

External input can not be used.

Initializing the Data Number with Clearing the Accumulated Data

When the data number is included with the data of the serial data output, initializing

the data number and clearing the accumulated data can be done at the same time.

Step 1

Press the key assigned to operate the function to display totAL and the

accumulated data.

Step 2

Press and hold the ZERO and +/- keys at the same time for more than 3 seconds.

The display blinks once and the accumulated data is cleared. And the data

number is initialized (1).

Caution