A&D Weighing AD-4406 User Manual

Page 57

Advertising
background image

AD-4406 Weighing Indicator

Page 55

16.

16.

16.

16.

4-20 mA Analog Output (OP-07)

4-20 mA Analog Output (OP-07)

4-20 mA Analog Output (OP-07)

4-20 mA Analog Output (OP-07)

The OP-07 analog output option is for sending the weight data to an analog input unit.

The output is a 4 mA to 20 mA current output proportional to the display reading.

The output data is updated in synchronization with the display update.

Specifications

Output current

4 mA to 20 mA *

Non-linearity

Less than +/

 0.1% fs

Load resistance

0 to 510

W

Temperature

ZERO

Less than +/

 0.02% fs/C

Resolution

Approx. 1/10000

coefficient

SPAN

Less than +/

 0.02% fs/C

Output terminal

Connector terminal No.1 : + No.2 :

 No.3 : FG (Earth)

Accessory

Connector terminal (1) TM-MSTB03STF
AC adapter (1)

Note: Please confirm that the AC adapter type is correct

for your local voltage and receptacle type.

* When set to a non-weight display (Calibration,

F-settings etc.), the output current is 4 mA.

The output current is not adjustable.

Settings

Set F30 of the F-Functions to 1, and set F31, F32 and F33.

Item

Parameter

Remarks

F30

*

ޓ0 No output

Initial setting

Data output

1 Analog output

Must be set to 1

2 Serial in/out 1

Data
output

3 Serial in/out 2

F31

*

ޓ0 Displayed value Initial setting

Output data

1 Gross weight
2 Net weight

F32
Weight value at 4 mA

999999 to 999999

(Initial setting is 0)

Decimal point is set
at “CALSEt”

Analog
output

F33
Weight value at 20 mA

-999999 to 999999

(Initial setting is 10000)

Decimal point is set
at “CALSEt”

Settings of F32 and F33

When entering the F32 or F33 settings (press the

ENTER key when “32” or “33” is blinking), the setting

value is displayed. Select the blinking digit by pressing

the key and increase the value by pressing the

1

key. By pressing the +/

 key, the polarity of the

value can be alternated. Press the ENTER key to

store the setting value into memory. After this the

display returns to selection of the Function number.

Analog output terminal



()







&%

DC 7V - 10V

AC adapter Jack

+

-

16. 4-20mA Analog Output (OP-07)

Output current

Weight

20m A

4m A

F32 a

F33 a

F32 b

F33 b

a

b

Advertising