Current Loop Output

Item

Parameter

Description

* 0

Displayed data

1

Gross data

2

Net data

3

Tare data

F36
Output data

4

Gross data/Net data/Tare data

0

Stream mode

1

Manual mode

2

Auto print mode (+)

3

Auto print mode (+/-)

4

When accumulation, automatically output

F37
Output mode

* 5

No output

* 0

No delay

F38
Delay for continual data

1

2.0 seconds (F36=4, except F37=0)

0

600 bps

1

1200 bps

F39
Baud rate

* 2

2400 bps

bps: bit per second

*: Initial settings

Serial Interface

tem

Parameter

Description

* 0

Stream mode, command is not acceptable

1

Manual mode, command is effective

2

Auto print mode (+) , command is effective

3

Auto print mode (+/-), command is effective

4

When accumulation, automatically output

F40
Output mode

5

Command mode

0

No output

* 1

Manual, Fixed format

2

Auto, Fixed format

3

Manual, Format 1 (F34)

4

Auto, Format 1 (F34)

5

Manual, Format 2 (F35)

F41
Accumulated data output
at accumulated data
display

6

Auto, Format 2 (F35)

* 0

No delay

1

0.5 second

2

1.0 second

3

1.5 seconds

F42
Delay for continual data

4

2.0 seconds

* 0

Not used

F43
Command address

1

Used (Address selected at F06)

* 0

Approx. 1 second

F44
Time out

1

No limitation

* 0

CR, LF

F45
Terminator

1

CR

*:

Initial settings