Commands to set serial data output format (ufc) – A&D Weighing AD-4406 User Manual

Page 52

Advertising
background image

Page 50

AD-4406 Weighing Indicator

Request Hold State

Request Hold State

Request Hold State

Request Hold State

When receiving this command, returns the average/hold state immediately.

Template

HD

Command

Reply

Not hold nor averaging

Averaging now

Hold

13.3.5. Commands to Set Serial Data Output Format (UFC)

Set Serial Data Format

Set Serial Data Format

Set Serial Data Format

Set Serial Data Format

Sets the serial output data format.

Format 1 data is stored in the same memory area of F34 and format 2 data is stored in

the same memory area of F35.

Template

SFf, [ parameters ]

f: Format number, 1 or 2

Command

Reply

13.4.

13.4.

13.4.

13.4. UFC Command

UFC Command

UFC Command

UFC Command

UFC (Universal Flexi Coms) function enables editing the serial data output format

freely using the serial interface command.

For customizing the print out of the printer or efficient data collection.

Output data is not only the indicator’s data/status, but also the characters at will.

It can output the control code* of the printer. (* depends on individual printer)

There are 2 sets of memories for storing the parameters.

UFC Command Parameter

UFC Command Parameter

UFC Command Parameter

UFC Command Parameter

UFC commands such as SF1 have many parameters.

One command line can have multiple parameters. The parameters are stored in

memory in order.

Multiple UFC commands are possible. The parameters are stored next to the last

parameter stored by the last UFC command.

Clear all of the data first, if storing a new set of parameters. The parameters in the

stored data can not be changed partially.

The various types of parameters and their descriptions are shown on the following

page.