A&D Weighing AD-4406 User Manual

Page 53

Advertising
background image

AD-4406 Weighing Indicator

Page 51

data

Weight, result of comparison etc.

$CL

CLear previous settings. The UFC command parameters can not be

changed partially.

$WT

Displayed data

$GR

GRoss data

$NT

NeT data

$TR

TaRe data

$HD

Header of Gross/Net/Tare. Refer to CF06.

$UT

Weight UniT

$ST

STable/Unstable

$CP

Result of ComParison

$ID

ID number specified at F06

$DN

Data Number increments with each output automatically

$CD

CoDe memory number

$AN

Accumulation count

$TL

TotaL weight

$CM

CoMma

$CR

CR code (0Dh)

$LF

LF code (0Ah)

$DE

DElete the last parameter

$DL

Inserting DeLay time (0.1 second step) Example: DL10 : 1.0 second delay

strings

Output the specified strings, enclosed by single quotation (’).

’ itself is described using three single quotations; ’’’

Example: ’A & D’

Set data bits = 8 bits if using the 8-bit characters.

hexadecimal Control code of the printer etc, preceded by #.

2 characters preceded by # is hexadecimal code (0 - 9, A - F).

Example: #09

The #FF code can not be used because it is used for internal

control.

Example

SF1,$ID$DN$CR$LF$GR$UT$CR$LF

Serial output data format 1, ID number, data number, carriage return and line

feed, Gross weight, unit, carriage return and line feed.

SF2,’ Welcome to A & D’$LF’Total weight ’$AN$TL$LF$LF

Serial output data format 2, the strings ’ Welcome to A & D’ and line feed, the

strings ’Total weight ’ accumulation count, total weight, and 2 sets of line

feed.

13.4. UFC Command

Advertising