background image

10 - Connect the Power and Ground

RocketLinx ES7510 User Guide: 2000544 Rev. B

Hardware Installation

b.

Tighten the wire-clamp screws to prevent the wires from coming loose.

• PWR1 and PWR2 support power redundancy and reverse polarity protection.

• If both power inputs are connected, the ES7510 is powered from the highest connected voltage.

• The ES7510 can emit an alarm if PWR1 or PWR2 are no longer receiving power.

2.

Connect a ground wire between the chassis and earth ground using 12-24AWG wire to ensure that the
ES7510 is not damaged by noise or electrical shock.

a.

Loosen the earth ground screw on the right side of the ES7510.

b.

Insert the ground wire.

c.

Tighten the ground screw after the earth ground wire is connected.

Electrical Specifications

Value

Power Input Voltage

DC1/DC2

IEEE 802.3af

48-57VDC

IEEE 802.3at

50-57VDC

Maximum PoE

Power/Port

IEEE 802.3af

15.4W

IEEE 802.3at

30W

Power Budget

PWR1/PWR2

220W

Total Power Budget

Up to 220W

Power Consumption

Without PD
load (max.)

28W

IEEE 802.3af
(max.)

144W

IEEE 802.3at
(max.)

262W