RocketLinx ES7510 User Guide: 2000544 Rev. B

Connect the Relay Output - 11

Hardware Installation

Connect the Relay Output

If desired, connect the Relay Output (DO). The
relay contacts are energized, (open) for normal
operation and close for fault conditions that can
be defined using the ES7510 web user interface
or Command Line Interface. See

Fault Relay

on

Page 109 or

Global Configuration Mode

on Page

131 for information about configuring events.
The events include:

Dry output

Port link failure

Ping failure

Ping reset

Ring failure

Note: The relay contact only supports 1A current

at 24VDC. Do not apply voltage and
current that exceeds these specifications.

Mount the ES7510

You can use the following procedure to mount the ES7510 on the wall.

Attach the brackets to the ES7510 by using the screws
provided in the plate mounting kit.

To avoid damage to the ES7510 circuitry, make sure that
you use the screws included in the plate mounting
package to attach and tighten the wall-mount plates
onto the ES7510. The screws are M3 and are 6 mm in
length.

The ES7510 will disperse heat through the metal case
during PoE port operation. The ES7510 should be
installed and mounted onto a panel that provides good
heat dispersion.

Connect the Ethernet Ports

You can use the following information to connect standard Ethernet cables between the ES7510 Ethernet
ports and the network nodes.

Ports 1-8 are Fast Ethernet (10/100BASE-TX) PoE ports that are IEEE 802.3af (PoE) and IEEE 802.3at
(PoE Plus) compliant.

Ports 9-10 are Gigabit (10/100/1000BASE-TX) ports.

Maximum Relay
Current

Extra Alarm
Power Source

Alert