Hardware installation, Connect the power and ground – Comtrol ES7510 User Manual

Page 9

Advertising
background image

RocketLinx ES7510 User Guide: 2000544 Rev. B

Hardware Installation - 9

Hardware Installation

You can use the following subsections to install the RocketLinx ES7510:

Connect the Power and Ground

Connect the Relay Output

on Page 11

Mount the ES7510

on Page 11

Connect the Ethernet Ports

on Page 11

LED Descriptions

on Page 13

Panel Layout

on Page 14

Connect the Power and Ground

You can use the following procedure to connect power and the ground to the ES7510.

1.

Connect the DC power inputs.

a.

Insert positive and negative wires (12-24AWG) into the PWR+ and PWR- contacts.

Note: Power should be disconnected from the power supply before connecting it to the switch.

Otherwise, your screw driver blade can inadvertently short your terminal connections to the
grounded enclosure.

Power Supply

48VDC - 57VDC/6A

V+

V-

AC Power Input

Power Supply

48VDC - 57VDC/6A

V+

V-

AC Power Input

12-24 AWG Wire