Comtrol ES7510 User Manual

Page 149

Advertising
background image

RocketLinx ES7510 User Guide: 2000544 Rev. B

Power over Ethernet (CLI) - 149

Configuration Using the Command Line Interface (CLI)

PoE Budget Warning (%)

Set

Switch> enable

Switch# config term

Switch(config)# interface fa1

Switch(config-if)# poe budget

auto Auto mode

manual Manual mode

warning Warning water level

Switch(config-if)# poe budget warning

<0-100> 0 is disable, valid range is 1 to 100 percentage

Switch(config-if)# poe budget warning 60

PoE Schedule Weekday Hour

Enable Hour 1, 3, 5
and 10 to 23 on
Sunday

Switch> enable

Switch# config term

Switch(config)# interface fa1

Switch(config-if)# poe schedule

<0-6> Weekday: valid range 0-6 (0=Sun, 1=Mon..., 6=Sat)

Switch(config-if)# poe schedule 0 1,3,5,10-23

Disable Sunday
Schedule

Switch(config-if)# no poe schedule 0

PoE Budget

Set

Switch(config)# poe

budget Configure the power budget of power over ethernet

pd-detect Configure PD status detection

Switch(config)# poe budget

<0-400> Power budget : 0 - 400 Watts

warning Warning water level

Switch(config)# poe budget 400

PoE PD Detect

Enable

Switch> enable

Switch# config term

Switch(config)# poe

disable Disables power over ethernet

enable Enables power over ethernet

budget Configure the power budget of power over ethernet

pd-detect Configure PD status detection

Switch(config)# poe pd-detect

disable Disable PD status detection

enable Enable PD status detection

A.B.C.D PD IP address

Switch(config)# poe pd-detect enable

Disable

Switch(config)# poe pd_detect disable

PoE PD Detect Cycle Time

Ping 20 Sec, Re-
enable PoE

Switch(config)# poe pd_detect 192.160.1.2 20