Page 19

Do not use automotive antifreeze. To help prevent

freezing, Laars recommends the use of inhibited

glycol concentrations between 20% and 35% glycol.

Typically, this concentration will serve as burst

protection for temperatures down to approximately

-5°F (-20°C). If temperatures are expected to be

lower than -5°F (-20°C), glycol concentrations up

to 50% can be used. When concentrations greater

than 35% are used, water flow rates must be
increased to maintain a 20°F to 25°F temperature
rise through the boiler.
Different glycol products may provide varying

degrees of protection. Glycol products must

be maintained properly in a heating system, or

they may become ineffective. Consult the glycol

specifications, or the glycol manufacturer, for

information about specific products, maintenance

of solutions, and set up according to your particular

conditions.
The following manufacturers offer glycols,

inhibitors, and anti foamants that are suitable for use

in the NeoTherm. Please refer to the manufacturers

instructions for proper selection and application.
• Sentinel Performance Solutions Group
• Hercules Chemical Company
• Dow Chemical Company

6a.4 ntH Suggested Piping Schematics

Figures 11 through 15 show suggested piping

configurations for NTH boilers. These diagrams

are only meant as guides. All components or piping

required by local code must be installed.