Page 76

When you are through, you shut off the

controller/burner you have been working with,

turn on the other controller/burner, and make

the same adjustments there.

WarnInG

Improper adjustment may lead to poor combustion

quality, increasing the amount of carbon monoxide

produced. Excess carbon monoxide levels may

lead to personal injury or death.

Required tools: Screwdrivers, Torx bits, combustion

analyzer

In the rest of this section we will explain the setup

procedure in more detail.

1. On the gas valve for the Primary burner on the

boiler, locate the adjustments for the high fire

CO

2

and low fire CO

2

. See Fig. 101.

Table 17 lists the CO

2

readings you should see

at high fire and low fire.

2. To start the setup, turn on the call for heat.
3. Before you can set up the Primary burner, you

must shut off the Secondary burner. Go to the

Home screen on the display. Press the icon for

the control labeled Secondary.

fig. 101 – High and low fire adjustments on

Gas Valve

High fire adjustment

Low fire adjustment

Gas Type

High Fire CO

2

Low Fire CO

2

Pressure Differential

Natural

8.5% ± 0.2

0.5% lower than high fire CO

2

0.5” to 1.2” wc*

Propane

9.5% ± 0.2

0.5% lower than high fire CO

2

0.5” to 1.2” wc*

* - Only check the pressures if there are problems getting the CO

2

and CO values in range.

table 17 – Co