Cino FA470 User Manual

Page 127

Advertising
background image

Command Descriptions

2-112

Parameter(s)

< Table 6-1-3 > Reply TS Operation Parameter(s) Field (Continued)

Parameter / PID / Size

Options

Descriptions

Data Transmission Packet

PID : 02h 04h

Size : 00h 01h (1 Byte)

- 00h
- 01h


Disable *
Enable

UPC/EAN Security Level

PID : 02h 06h

Size : 00h 01h (1 Byte)

- 00h
- 01h
- 02h


Level 0
Level 1 *
Level 2

Supplement Scan Voting

PID : 02h 08h

Size : 00h 01h (1 Byte)

- 00h
- 06h
- 08h
- 0Ah
- 0Ch
- 0Eh
- 10h


- 12h
- 14h
- 16h
- 18h
- 1Ah
- 1Ch
- 1Eh


None
Level 1
Level 2
Level 3 *
Level 4
Level 5
Level 6


Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13

Laser Aiming Control

PID : 02h 09h

Size : 00h 01h (1 Byte)

- 00h
- 01h

(See Notes)

Disable
Enable *

LED Illumination

PID : 02h 0Bh

Size : 00h 01h (1 Byte)

- 00h
- 01h

(See Notes)

Always on
Intelligent Scanning *

Illumination Delay Duration

PID : 02h 0Ch

Size : 00h 01h (1 Byte)


- 00h
- 01h
- 02h
- 03h
- 04h

(See Notes)

100ms
200ms
300ms
400ms
500ms

Operation Mode
(Tethered Scanner)

PID : 10h 00h

Size : 00h 01h (1 Byte)


- 00h
- 01h
- 02h
- 04h
- 05h
- 06h
- 07h
- 08h
- 09h


Trigger mode (External triggering) *
Force mode (Continued power on)
Presentation mode (Auto detection)
Level mode (Auto power off)
Diagnostic mode (Test reading)
Alternative mode (Periodic power off)
Toggle mode (Repeat reading)
Flash mode (Pulse driven reading)
Low Power mode (Low Power triggering)

.

Notes

1.

LED Illumination, Illumination Delay Duration are only available for L680, L688, L780, L788

2.

Laser Aiming Control is only available for L688, L788

Advertising