Master default – Cino FA470 User Manual

Page 37

Advertising
background image

Command Descriptions

2-22

Master Default

(ALL)

Descriptions

Set all parameters to the factory default except for the interface settings

The host interface related parameters still remain the same after performing the Master Default
command.

For Bluetooth L & F Series:

Set all parameters to the factory default settings except for the following parameters:
Handshaking Protocol, Baud Rate, Data Frame, Serial Response Timeout, Bluetooth Device Name,
Bluetooth PIN Code, Out-of-range Scanning, Interface Delay Settings.
And the radio link is still on.

For Wi-Fi L & F Series:

Restore Scanner Settings and keep Fonts, Language Pack, Batch Records, Wi-Fi Profile, System
Settings, Interface Settings, Online Scanning and Batch Scanning Settings.
And the radio link is still on.

Packet Format

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

80h 04h 01h

00h

00h 00h

<Null>

85h

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

0 Byte

1 Byte

1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a “Device ACK” will be sent

to the host right after the device performed the action. Otherwise, a “Device NAK will be sent to host to

issue a command error. However, if the host can not receive any response from the device within the

user preset time-out duration, please resend the above command.

. Parameter(s) Field

Master Default command takes no parameters, so the Parameter(s) field is null.


. Length

Total size (bytes) of the Parameter(s) field

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”

Advertising