Command Descriptions
2-178
Reply Transmission
(ALL)
Descriptions
Reply the desired one or more parameters of the Transmission settings as well as DataWizard
Premium parameters including Data Script Active Setting, Data Script Setting, Security Script
Setting and Data Wizard Premium Error Message.
Reply Transmission is sent by the device in response to the Get Transmission command. It sends
the values for all the desired parameters requested in the Get Transmission command.
DataWizard Premium parameters are only available for Scanners that support DataWizard
Premium. For more details about DataWizard Premium, please refer to FuzzyScan DataWizard
Premium User Manual.
Packet Format
Prefix
Opcode
Status
Length
Parameter(s)
LRC
Suffix
7Eh
0Dh 00h 00h
00h
Variable
See Below
Variable
7Eh
1 Byte
3 Bytes
1 Byte
2 Bytes
Variable
1 Byte
1 Byte
Parameter(s)
First Parameter
………
Last Parameter
PID
Size
Options ………
PID
Size
Options
2 Bytes 2 Bytes Variable ……… 2 Bytes 2 Bytes Variable
See Next Page
. Host Requirements
Since Reply Transmission is a device-to-host message, there is no response for this message.
. Parameter(s) Field
Reply Transmission can change multiple parameters at one time, so it takes compound parameters.
. Length
Total size (bytes) of the Parameter(s) field
. LRC
”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”
. Size
Total size (bytes) of the Options field