Command Descriptions

2-121

Reply SE Operation

(SE)

Descriptions

Reply the desired one or more parameters of the Operation Settings for Scan Engine
Reply SE Operation is sent by the device in response to the Get SE Operation command. It sends
the values for all the desired parameters requested in the Get SE Operation command.
Available for SE380, SE390 & SE480 series

Packet Format

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

0Ah 00h 00h

00h

Variable

See Below

Variable

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

Variable

1 Byte

1 Byte

Parameter(s)

First Parameter

………

Last Parameter

PID

Size

Options ………

PID

Size

Options

2 Bytes 2 Bytes Variable ……… 2 Bytes 2 Bytes Variable

See Next Page

. Host Requirements

Since Reply SE Operation is a device-to-host message, there is no response for this message.

. Parameter(s) Field

Set SE Operation can change multiple parameters at one time, so it takes compound parameters.


. Length

Total size (bytes) of the Parameter(s) field

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”


. Size

Total size (bytes) of the Options field