Paging – Cino FA470 User Manual

Page 48

Advertising
background image

Command Descriptions

2-33

Paging

(WF)

Descriptions

Paging the scanner
This command is helpful for you to locate the connected Wi-Fi scanner.
Available for F & L series

Packet Format

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

80h 90h 01h

00h

00h 00h

<Null>

5Ch 04h

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

0 Byte

1 Byte

1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a “Device ACK” will be sent

to the host right after the device performed the action. Otherwise, a “Device NAK will be sent to host to

issue a command error. However, if the host can not receive any response from the device within the

user preset time-out duration, please resend the above command.

. Parameter(s) Field

Store Configuration command takes no parameters, so the Parameter(s) field is null.


. Length

Total size (bytes) of the Parameter(s) field

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”

Serial Command
Paging the scanner
0x7e 0x80 0x90 0x01 0x00 0x00 0x00

0x5c 0x04

0x7e









.

Notes

0x5C 0x04: the escaped value of 0x11.