1 communication get connected mac – Cino FA470 User Manual

Page 17

Advertising
background image

Command Descriptions

2-2

2.1 Communication

Get Connected MAC

(BT)

Descriptions

Get the connected scanners’ MAC addresses
This command is used when working with the SmartCradle in PICO mode.
Available for F, L & A series

Packet Format

Prefix

Opcode

Status

Length

PID

Size

LRC

Suffix

7Eh

D6h FFh FFh

00h

00h 04h

FFh 00h

00h 00h

2Dh

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

2 Bytes

2 Bytes

1 Byte

1 Byte


. Host Requirements

If the device successfully received the above command issued by the host, a “Device ACK” will send to

the host right after the device performed the action. Otherwise, a “Device NAK will be sent to host to

issue a command error. However, if the host can not receive any response from the device within the

user preset time-out duration, please resend the above command.

. Length

Total size (bytes) of the Parameter(s) field

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”

. Size

Total size (bytes) of the Options field