Command Descriptions

2-128

Parameter(s)

< Table 5-3 > Set FS Operation Parameter(s) Field (Continued)

Parameter / PID / Size

Options

Descriptions

OK/NG Active Signal Control

PID : 20h 01h

Size : 00h 03h (3 Bytes)

1

st

Byte

- 00h
- 01h
- 02h
- 03h

2

nd

Byte

- 00h
- 01h
- 02h
- 03h

3

rd

Byte

- 01h
- 02h
- 03h
- 04h
- 05h
- 06h
- 07h
- 08h
- 09h
- 0Ah
- XXh

OK/NG Active Signal Output

Disable
Enable NG only
Enable OK only
Enable*

OK/NG Active Signal State

OK Low/ NG Low*

OK Low/ NG High
OK High/ NG Low
OK High/ NG High

OK/NG Active Duration

10ms
20ms
30ms
40ms
50ms
60ms
70ms
80ms
90ms
100ms *
User-defined (See Note under the table)

OK/NG Beep Control

PID : 20h 02h

Size : 00h 02h (2 Bytes)

1

st

~2

nd

Byte

- 00h 00h
- 01h 01h
- 00h 01h
- 01h 00h


Disable
Enable *
Enable OK only
Enable NG only

Scan Input Time-out

PID : 20h 03h

Size : 00h 01h (1 Byte)

- 00h
- 01h
- 02h
- 03h
- 04h
- 05h
- 06h
- 07h
- 08h
- XXh


100ms
200ms
300ms
400ms
500ms
600ms
700ms
800ms
900ms*
User-defined (See Note under the table)

. Notes

1.

OK/ NG Active Duration can be set to User-defined 1~99(×5) milliseconds. XXh = desired

milliseconds (h) + 80h. For example, if you want to set it to 99

(×5) ms (the actual value is 495 ms),

you need to convert 99 from Dec to Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.

2.

Scan Input Time-out can be set to User-defined 1~99 seconds. XXh =desired seconds (h) + 80h.

For example, if you want to set this parameter to 99 seconds, you need to convert 99 from Dec to

Hex, that is, 63h. Then, XXh = 63h + 80h = E3h.