3 image enter capture image mode – Cino FA470 User Manual

Page 27

Advertising
background image

Command Descriptions

2-12

2.3 Image

Enter Capture Image Mode

(TS)

Descriptions

Enter Capture Image Mode
Once scanner is entered the Capture Image Mode, you can trigger the scanner to capture image
repeatedly, after every image is captured and ready to be retrieved, scanner will send out a Capture
Image Ready Notify
packet to host, and then the host can send Get Capture Image Data
command to retrieve the image data.
Available for A series

Packet Format

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

80h 1Ah 00h

00h

00h 0Ah

See below

Variable

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

10 Bytes

1 Byte

1 Byte


. Host Requirements

If the device successfully received the above command issued by the host, a “Device ACK” will be sent

to the host right after the device performed the action. Otherwise, a “Device NAK will be sent to host to

issue a command error. However, if the host can not receive any response from the device within the

user preset time-out duration, please resend the above command.

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”

Parameter(s)

Size

Parameter

Descriptions

1 Byte

Type

- 00h Photo
- 01h Video

1 Byte

Format

- 00h 8 bits BMP
- 01h 32 bits BMP
- 02h JPG
- 03h PNG

1 Byte

Aimer

- 00h Without Aimer
- 01h With Aimer

1 Byte

AE

- 00h Fixed Exposure
- 01h Auto Exposure

2 Bytes
(Big Endian)

Exp Level
(The higher value the
longer exposure time
will be used)

- 0001h Level 1
- 0002h Level 2
- ……(Range from Level 1 ~ 24)
- 0018h Level 24

4 Bytes

Timeout

Reserved (Always 00h)

Advertising