Fs test mode – Cino FA470 User Manual

Page 42

Advertising
background image

Command Descriptions

2-27

FS Test Mode

(FS)

Descriptions

Set the Fixed Mount and Scan Module to Test Mode.
You may refer to “FuzzyScan Fixed Mount Scanner Programming Manual “or “FuzzyScan Fixed
Mount Scanner Quick Start Guide” for more details about the Test Mode.
Available for FM480, FA470, SM380 & SM5700 series

Packet Format

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

80h 06h 00h

00h

00h 01h

See Below

Variable

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

1 Byte

1 Byte

1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a “Device ACK” will be sent

to the host right after the device performed the action. Otherwise, a “Device NAK will be sent to host to

issue a command error. However, if the host can not receive any response from the device within the

user preset time-out duration, please resend the above command.


. Length

Total size (bytes) of the Parameter(s) field

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”

Parameter(s)

< Table 4-2 > FS Test Mode Parameter(s) Field

Parameter / PID / Size

Options

Descriptions

FS Test Mode

PID : <Null>

Size : 00h 01h (1 Byte)


- 00h
- 01h


Fixed Reader Enter Test Mode 0
Fixed Reader Enter Test Mode 1