Cino FA470 User Manual

Page 156

Advertising
background image

Command Descriptions

2-141

Parameter(s)

< Table 6-4-1 > Set BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size

Options

Descriptions

Laser Aiming Control

PID : 02h 09h

Size : 00h 01h (1 Byte)

- 00h
- 01h


Disable
Enable *

LED Illumination

PID : 02h 0Bh

Size : 00h 01h (1 Byte)

- 00h
- 01h


Always on
Intelligent Scanning *

Illumination Delay Duration

PID : 02h 0Ch

Size : 00h 01h (1 Byte)


- 00h
- 01h
- 02h
- 03h
- 04h


100ms
200ms
300ms
400ms
500ms

Operation Mode
(Bluetooth A Series)

PID : 70h 00h

Size : 00h 03h (3 Bytes)


- 00h 01h 01h
- 02h 01h 01h


Trigger mode *
Presentation mode

Hand-Held Mode Illumination
& Aiming Control

PID : 70h 01h

Size : 00h 01h (1 Byte)

Bit 0

- 0
- 1

Bit 1

- 0
- 1

Hand-Held Decode Aiming Control

Disable
Enable *

Hand-Held Illumination Control

Disable
Enable *

Hand-Free Mode Decode
Aiming Control

PID : 70h 02h

Size : 00h 01h (1 Byte)

- 02h
- 03h


Disable
Enable *

Aiming Control

PID : 70h 03h

Size : 00h 02h (2 Bytes)

- 00h 00h
- 01h 00h
- 00h 03h


Regular Aiming *
Intelligent Aiming
Delay Aiming Control







.

Notes

1.

LED Illumination, Illumination Delay Duration are only available for L680BT, L688BT, L780BT,

L788BT.

2.

Laser Aiming Control is only available for L688BT, L788BT

3.

Hand-Held Mode Illumination & Aiming Control, Hand-Free Mode Decode Aiming Control and

Aiming Control are available for A Series only.

Advertising