Serial trigger – Cino FA470 User Manual

Page 34

Advertising
background image

Command Descriptions

2-19

Serial Trigger

(ALL)

Descriptions

Start or Stop a scan session
When triggered on, the scanner attempts to obtain the requested data. When triggered off, the
scanner aborts a decode attempt.

Packet Format

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

80h 02h 00h

00h

00h 01h

See

<Table 1-2>

Variable

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

1 Byte

1 Byte

1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a “Device ACK” will be sent

to the host right after the device performed the action. Otherwise, a “Device NAK will be sent to host to

issue a command error. However, if the host can not receive any response from the device within the

user preset time-out duration, please resend the above command.


. Length

Total size (bytes) of the Parameter(s) field

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”

Parameter(s)

< Table 1-2 > Serial Trigger Parameter(s) Field

Parameter / PID / Size

Options

Descriptions

Serial Trigger

PID : <Null>

Size : 00h 01h (1 Byte)


- 00h
- 01h


OFF
ON

Advertising