Cino FA470 User Manual

Page 163

Advertising
background image

Command Descriptions

2-148

Parameter(s)

< Table 6-4-3 > Reply BT Operation Parameter(s) Field (Continued)

Parameter / PID / Size

Options

Descriptions

UPC/EAN Security Level

PID : 02h 06h

Size : 00h 01h (1 Byte)

- 00h
- 01h
- 02h


Level 0
Level 1 *
Level 2

Supplement Scan Voting

PID : 02h 08h

Size : 00h 01h (1 Byte)

- 00h
- 06h
- 08h
- 0Ah
- 0Ch
- 0Eh
- 10h


- 12h
- 14h
- 16h
- 18h
- 1Ah
- 1Ch
- 1Eh


None
Level 1
Level 2
Level 3 *
Level 4
Level 5
Level 6


Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13

Operation Mode
(Bluetooth F & L Series)

PID : 50h 00h

Size : 00h 01h (1 Byte)

- 00h
- 02h


Trigger mode (External triggering) *
Presentation mode (Auto Detection)

Batch Scanning Link Control

PID : 51h 00h

Size : 00h 01h (1 Byte)

- 00h
- 01h


Radio Disable
Radio Enable *

Stored Data Transmission

PID : 51h 01h

Size : 00h 01h (1 Byte)

- 00h
- 01h
- 02h


All *
On-cradle
Scan Barcode

Delete Stored Data After
Transmission

PID : 51h 02h

Size : 00h 01h (1 Byte)


- 00h
- 01h



Disable *
Enable

Field Delimiter

PID : 51h 03h

Size : 00h 01h (1 Byte)

- 00h
- 2Ch
- 20h


- 2Dh
- 2Eh
- XXh


None
<,> *
<SPACE>


<->
<.>
User-defined 00~7Fh

Batch Data Quantity Output
Format

PID : 51h 04h

Size : 00h 01h (1 Byte)

- 00h
- 01h
- 02h


As many times as the quantity indicates *
<Quantity><Field Delimiter><Data>
<Data><Field Delimiter><Quantity>





.

Warning

If you are using the SmartCradle to communicate with the Scanner, “BT Synchronization” command

should be sent to the scanner after the setting of the “Field Delimiter” to sync the Scanner with the

SmartCradle, so that the settings will take effect immediately.

Advertising