Command Descriptions

2-190

Parameter(s)

< Table 8-1-1 > Set Symbology Parameter(s) Field (To be continued)

Parameter / PID / Size

Options

Descriptions

Code 39 Readability

PID : 00h 00h

Size : 00h 01h (1 Byte)


- 00h
- 01h


Disable
Enable *

Code 39 Setting

PID : 00h 01h

Size : 00h 06h (6 Bytes)

1

st

Byte

- 00h
- 01h
- 02h

2

nd

Byte

- 00h
- 01h

3

rd

Byte

- 00h
- 01h

4

th

Byte

- 00h
- 01h

5

th

Byte

- 00h
- 01h

6

th

Byte

- 00h
- 01h

Primary Format Selection

Standard Code 39 *
Full ASCII Code 39
Code 32 (Italian Pharmaceutical)

Start/ Stop Symbol Transmission

Disable *
Enable

Code 32 Leading A Transmission

Disable *
Enable

MOD 43 Check Digit Verification

Disable *
Enable

Check Digit Transmission

Disable *
Enable

Code 39 Buffering

Disable *
Enable

Code 39 Length

PID : 00h 02h

Size : 00h 02h (2 Bytes)

1

st

Byte

- 01h~62h

2

nd

Byte

- 62h~01h

Minimum Length

1~98 (Default: 1)

Maximum Length

98~1 (Default: 98)

Trioptic Code 39 Readability

PID : 00h 03h

Size : 00h 01h (1 Byte)


- 00h
- 01h


Disable *
Enable

Code 39 Security Level

PID : 00h 04h

Size : 00h 01h (1 Byte)


- 00h
- 01h
- 02h
- 03h


Level 0
Level 1
Level 2 *
Level 3