Fs a operation mode – Cino FA470 User Manual

Page 44

Advertising
background image

Command Descriptions

2-29

FS A Operation Mode

(FS)

Descriptions

Select operation mode for Fixed Mount and Scan Module
FS A Operation Mode is equivalent to the Operation Mode Selection in the Set FS Operation
command. It is of more convenience to use FS A Operation Mode of the Action Command Category.
Available for FA470 & SM5700 series

Packet Format

Prefix

Opcode

Status

Length

Parameter(s)

LRC

Suffix

7Eh

80h 08h 05h

00h

00h 03h

See Below

Variable

7Eh

1 Byte

3 Bytes

1 Byte

2 Bytes

3 Bytes

1 Byte

1 Byte

. Host Requirements

If the device successfully received the above command issued by the host, a “Device ACK” will be sent

to the host right after the device performed the action. Otherwise, a “Device NAK will be sent to host to

issue a command error. However, if the host can not receive any response from the device within the

user preset time-out duration, please resend the above command.


. Length

Total size (bytes) of the Parameter(s) field

. LRC

”Opcode” XOR “Status” XOR “Length” XOR “Parameter(s)”

Parameter(s)

< Table 4-3 > FS A Operation Mode Parameter(s) Field

Parameter / PID / Size

Options

Descriptions

FS A Operation Mode

PID : <Null>

Size : 00h 03h (3 Byte)


- 00h 01h 01h
- 01h 01h 01h
- 02h 01h 01h
- 04h 01h 00h
- 06h 01h 00h


Trigger mode *
Force mode
Presentation mode
Level mode
Alternative mode